OUTDOOR solution

Urban Lighting

  Oldcity20 SMALL

S-OTP 10-60W


LED lighting urban fixture for street lighting, parks, boulevards, gardens, piers, squares, parking lots, pedestrian and bicycle paths.


Die-cast aluminum body with high mechanical strength

Grey color paint with 8,000-hour salt spray treatment

Optics: secondary lens type S-OTP multilayer

LED source efficiency >230lm/W Ta 25°C Tj 25°C;

LED source color temperature: 4000K (2700K,3000K, 5000K on request);

Total weight 7.60kg

Dimensions 350mm x 350mm x 680mm

CRI ≥70;

IP66 degree of protection;

Mechanical resistance IK10 (body);

IP67 quick line connector;

Insulation class: II (class I on request);

Power supply: 220÷240V - 50/60Hz;

Power factor: > 0.90;

Overvoltage protection up to 10KV;

Mounting : Top Pole TP, hanging S on shelf or curved pole, standing AP, chain C; 

Ø60mm pole connection or 1/2" GAS connection.

Various remote control systems: radio waves / conveyed waves / bluetooth / zigbee 

Standards: CEI EN 60598-1; CEI EN 60598-2-03; CEI EN 62031; 2014/30/EC (EMC);

Essential and compact design.

Installation top pole or lateral on boom. 


Mounting : Top Pole TP, hanging S on shelf or curved pole, standing AP, chain C; 


350mm x 350mm x 680 mm 


Pole attachment: 

diam. 60mm


Suspension attachment:

1/2" GAS

Innovative solutions, technical excellence, design flexibility for street lighting.

S-OTP Series

3000K / 4000K / 5700K

CRI > 70


Oldcity 20 S- 10W

Oldcity 20 S- 20W

Oldcity 20 S- 30W

Oldcity 20 S- 40W

Oldcity 20 S- 60W

(*) Other wattages / CRI / CCT available on request


N.B: In order to encourage constant updating of its products, LUMEITALIA informs that LED flux and wattage values are subject to continuous change. 

LUMEITALIA reserves the right to make changes without prior notice.


OLDCITY20 series


LED lighting urban fixture for street lighting, parks, boulevards, gardens, piers, squares, parking lots, pedestrian and bicycle paths.


PRODUCT CODE TABLE ORDER

ITEM CODE Types of attacks Total power CRI CCT Optics Control system1 Control system2 Control system3 Control system4 Control system5 CLASS
(Y) (A) (B) (C) (D) (E) (F) (G) (H) (I) (L)
CODE TP=Top pole 10W = 10 CRI 70 = 7 CCT 3000K = 30 Road = ST DALI = DA 1-10V = 10V LUMEfi = LF VIRTUAL MID. = MV NEMA = NM CLASS I = 01
CODE S=hanging 20W = 20 CRI 80 = 8 CCT 4000K = 40 Cycle-pedestrian path=CP ZHAGA=ZH ZHAGA=ZH CLASS II = 02
CODE AP=in support 30W = 30 CRI 90 = 9 (*) CCT 5700K = 57 Rotosymmetrical=RT WIRELESS=OR WIRELESS=OR
CODE C=chain 40W = 40 CCT 2200K = 22 (*) Other optics = (*) POWER LINE = OC POWER LINE = OC
CODE 50W = 50 CCT 2700K = 27 (*)
CODE 60W = 60 CCT 5000K = 50 (*)
(*) On request Other powers = (*) CCT 6000K = 60 (*)


COMPOSITION PRODUCT CODE ORDER

FAMILY CODE TYPES OF ATTACKS TOTAL POWER CRI CCT OPTICS CONTROL SYSTEM CLASS
BASE CODE column (Y) column (A) column (B) column (C) column (D) column (E) column (L)
OLD20S = OLDCITY20 SMALL TP=Top pole 20 = 20W 7 = CRI 70 40 = 4000K ST = Road DA = Dali 02 = Class II
OLD20S TP 20 7 40 ST DA 02


PRODUCT CODE : OLD20STP20-740STDA02


TABLEOLDCITY20 SMALL 3000K

OLDCITY20 MD Attack types Total Power CRI- CCT- Types of optics Lumen Lumen Control system1 Control system2 Control system3 Control system4 Control system5 Class-
BASIC CODE (Y) (A) (B) (C) (D) LED SYSTEM (E) (F) (G) (H) SMART CONTROL SYSTEM (L)
OLD20S(Y)(A)-(B)(C) TP-S-AP-C W Ra K ST-RT-AS-CP Lm at Tj25°C Lm at Tj25°C DALI 1-10V LUME-FI VIRTUAL MID. (I) I - II
OLDS(Y)10-730 TP-S-AP-C 10 7 30 ST-RT-AS-CP 2.270 1.488 DA 10V LF MV NM-ZH-OR-OC 01 - 02
OLDS(Y)20-730 TP-S-AP-C 20 7 30 ST-RT-AS-CP 4.540 2.976 DA 10V LF MV NM-ZH-OR-OC 01 - 02
OLDS(Y)30-730 TP-S-AP-C 30 7 30 ST-RT-AS-CP 6.810 4.406 DA 10V LF MV NM-ZH-OR-OC 01 - 02
OLDS(Y)40-730 TP-S-AP-C 40 7 30 ST-RT-AS-CP 9.080 5.875 DA 10V LF MV NM-ZH-OR-OC 01 - 02
OLDS(Y)50-730 TP-S-AP-C 50 7 30 ST-RT-AS 11.350 7.248 DA 10V LF MV NM-ZH-OR-OC 01 - 02
OLDS(Y)60-730 TP-S-AP-C 60 7 30 ST-RT-AS 13.620 8.698 DA 10V LF MV NM-ZH-OR-OC 01 - 02


TABLEOLDCITY20 SMALL4000K

OLDCITY20 S Attack types Total Power CRI- CCT- Types of optics Lumen LUMEN Control system1 Control system2 Control system3 Control system4 Control system5 Class-
BASIC CODE (Y) (A) (B) (C) (D) LED SYSTEM (E) (F) (G) (H) SMART CONTROL SYSTEM (L)
OLD20S(Y)(A)-(B)(C) TP-S-AP-C W Ra K ST-RT-AS-CP Lm at Tj25°C Lm at Tj25°C DALI 1-10V LUME-FI VIRTUAL MID. (I) I - II
OLDS(Y)10-740 TP-S-AP-C 10 7 40 ST-RT-AS-CP 2.300 1.550 DA 10V LF MV NM-ZH-OR-OC 01 - 02
OLDS(Y)20-740 TP-S-AP-C 20 7 40 ST-RT-AS-CP 4.600 3.100 DA 10V LF MV NM-ZH-OR-OC 01 - 02
OLDS(Y)30-740 TP-S-AP-C 30 7 40 ST-RT-AS-CP 6.900 4.590 DA 10V LF MV NM-ZH-OR-OC 01 - 02
OLDS(Y)40-740 TP-S-AP-C 40 7 40 ST-RT-AS-CP 9.200 6.120 DA 10V LF MV NM-ZH-OR-OC 01 - 02
OLDS(Y)50-740 TP-S-AP-C 50 7 40 ST-RT-AS 11.500 7.550 DA 10V LF MV NM-ZH-OR-OC 01 - 02
OLDS(Y)60-740 TP-S-AP-C 60 7 40 ST-RT-AS 13.800 9.300 DA 10V LF MV NM-ZH-OR-OC 01 - 02


NOTE: In order to encourage constant updating of its products, LUMEITALIA informs that the flux and power values of the LEDs are subject to continuous variations. LUMEITALIA reserves the right to make changes without notice.

Share by: