WALL A/B 1750: technical selection and application guide
What WALL A/B 1750 is, which indoor lighting projects it fits, which regulatory requirements to verify and how to specify it.
Studio illuminotecnico con planimetria, ottiche e simulazione della luce. Immagine illustrativa generata con AI.
Overview
WALL A/B 1750 — Applique lineare ultra-slim 1725 mm · 46W · CREE Premium. Apparecchio da parete a luce diffusa con profilo ultra-slim da 25 mm e lunghezza 1725 mm. Perfetto per hotel, reception, retail, corridoi e ambienti direzionali. This Centro Studi briefing does not replace the product page: it frames the luminaire within the design process, from requirement definition to on-site verification.
Where it is used
WALL A/B 1750 belongs to the indoor lighting scope and is used in offices, retail, schools, healthcare and commercial spaces. Three items always come first: classification of the scope under the applicable standard, the real installation geometry (spacings, heights, brackets or pitches) and the maintenance conditions planned over the installation life cycle.
Hotel e reception
Ristoranti
Centri commerciali e retail
Corridoi e spazi comuni
Uffici e direzionali
Build characteristics
Photometric data: Specific photometric values (flux, efficacy, expected illuminance) are not published in generic form because they depend on configuration and installation geometry. Photometric files for calculation are available from the technical office at info@lumeitalia.it.
Profilo ultra-slim 25 mm · L1725×W25×H75 mm
46W (23W×2) · doppio corpo indipendente
LED CREE Premium · CRI ≥80
CCT 4000K standard (2700/3000/6500K su richiesta)
Angolo 120° · luce diffusa
IP20 standard (IP44/IP54 su richiesta)
Driver Constant Current ON/OFF (0/1-10V opzionale)
Corpo in alluminio pressofuso · colori nero/grigio/bianco/custom
Potenza — 46W (23W×2)
CCT — 4000K
CRI — ≥80
Protezione — IP20
Vita utile — ≥50.000h (L70/B50)
Materiale — Alluminio pressofuso
Regulatory requirements to verify
The requirement must be stated before product selection and repeated at commissioning with the same measurement method. A requirement written without a reference standard and without verification conditions is the most frequent cause of dispute at acceptance.
EN 12464-1 — illuminance, UGR and uniformity per visual task
EN 17037 — daylight integration
GPP criteria — minimum environmental criteria for public buildings
Scope classified under the applicable standard, with the risk analysis attached
Performance requirements stated with standard, measurement point and conditions
Maintenance factor justified and consistent with the cleaning plan
Photometric files requested from the supplier for the design calculation
Ingress protection, impact resistance and electrical class matched to the site
Dimming system and control protocol defined in the specification
Warranty terms, spare parts and maintenance accessibility
Installation, operation and maintenance
During installation the main variables are aiming, tightening of the fixings and correct execution of the electrical terminations. In operation, the maintenance plan must state the cleaning frequency of the optical surfaces, periodic gasket checks and how electronic components are replaced.
Declared marks and ratings for the range: CE, RoHS. The related documents are supplied with the order confirmation.
Alternatives in the same family
I-PAN: Pannelli LED professionali UGR<19
ALTAVIA Pannel LED BK Lite: Pannello LED professionale backlit da incasso o superficie per uffici, retail, ambienti commerciali e struttur
CIELO Low UGR RD3013: Downlight LED da incasso UGR<19 · Lumileds 3030
WALL A/B 1750 is a defensible choice when indoor lighting requirements are stated, the calculation reproduces the real geometry and commissioning follows an agreed protocol. The full datasheet and quotation request are on the product page: https://lumeitalia.it/prodotti/wall-ab-1750. The technical office is available for design requirement reviews at info@lumeitalia.it.
Domande frequenti
Which projects should consider WALL A/B 1750?+
Indoor lighting projects covering offices, retail, schools, healthcare and commercial spaces. Suitability starts from scope classification and real geometry, not from datasheet comparison.
Which documents should be requested before specifying WALL A/B 1750?+
Photometric files for the proposed luminaires, declaration of conformity, declared lifetime data per IES LM-80 with its conditions, maintenance schedule and warranty terms.
Is WALL A/B 1750 suitable for retrofitting an existing installation?+
It depends on the inherited geometry: existing spacings and heights must be checked with a dedicated calculation before confirming a one-for-one replacement. The technical office runs the check on request.
Why are photometric values not published?+
Because an out-of-context figure cannot be verified: the result depends on configuration, optic and installation geometry. Photometric files are available at info@lumeitalia.it.
Lumeitalia — Sistemi LED professionali
Lumeitalia è il brand di illuminazione LED professionale di Mya Tech S.r.l., azienda italiana fondata nel 2011 a Trezzano sul Naviglio (MI); il brand è attivo dal 2020.