Lumeitalia

Caricamento

Il caricamento sta impiegando più tempo del previsto.

Torna alla home

Lumeitalia

ALTAVIA Pannel LED BK Lite: technical selection and application guide

What ALTAVIA Pannel LED BK Lite is, which indoor lighting projects it fits, which regulatory requirements to verify and how to specify it.

Studio illuminotecnico con planimetria, ottiche e simulazione della luce
Studio illuminotecnico con planimetria, ottiche e simulazione della luce. Immagine illustrativa generata con AI.

Overview

ALTAVIA Pannel LED BK Lite. Pannello LED professionale backlit da incasso o superficie per uffici, retail, ambienti commerciali e strutture sanitarie. Ex serie I-PAN BK, evoluta nella nuova architettura di brand ALTAVIA Pannel. This Centro Studi briefing does not replace the product page: it frames the luminaire within the design process, from requirement definition to on-site verification.

Where it is used

ALTAVIA Pannel LED BK Lite belongs to the indoor lighting scope and is used in offices, retail, schools, healthcare and commercial spaces. Three items always come first: classification of the scope under the applicable standard, the real installation geometry (spacings, heights, brackets or pitches) and the maintenance conditions planned over the installation life cycle.

  • Uffici
  • Retail
  • Ambienti commerciali
  • Strutture sanitarie
  • Sale riunioni
  • Scuole

Build characteristics

Photometric data: Specific photometric values (flux, efficacy, expected illuminance) are not published in generic form because they depend on configuration and installation geometry. Photometric files for calculation are available from the technical office at info@lumeitalia.it.

  • Tecnologia backlit ad alta luminosità
  • CRI >80 · SDCM 4 step
  • Spessore ridotto 30-33 mm
  • Corpo SPCC + cornice AL6063 + diffusore PS · RAL 9003
  • Installazione da incasso T-Grid o a superficie
  • Alimentazione 220-240Vac 50/60Hz · DALI opzionale
  • Certificazioni CE · RoHS · LM80 · IES · Garanzia 5 anni
  • Potenza — 25-36 W
  • CCT — 4000K standard · 2200-5700K a richiesta
  • CRI — >80
  • UGR — 22
  • Protezione — IP20
  • Vita utile — L70 >50.000h
  • Spessore — 30-33 mm
  • Materiale — SPCC + AL6063 + diffusore PS

Regulatory requirements to verify

The requirement must be stated before product selection and repeated at commissioning with the same measurement method. A requirement written without a reference standard and without verification conditions is the most frequent cause of dispute at acceptance.

  • EN 12464-1 — illuminance, UGR and uniformity per visual task
  • EN 17037 — daylight integration
  • GPP criteria — minimum environmental criteria for public buildings
  • Scope classified under the applicable standard, with the risk analysis attached
  • Performance requirements stated with standard, measurement point and conditions
  • Maintenance factor justified and consistent with the cleaning plan
  • Photometric files requested from the supplier for the design calculation
  • Ingress protection, impact resistance and electrical class matched to the site
  • Dimming system and control protocol defined in the specification
  • Warranty terms, spare parts and maintenance accessibility

Installation, operation and maintenance

During installation the main variables are aiming, tightening of the fixings and correct execution of the electrical terminations. In operation, the maintenance plan must state the cleaning frequency of the optical surfaces, periodic gasket checks and how electronic components are replaced.

Declared marks and ratings for the range: CE, RoHS, LM-80, IES. The related documents are supplied with the order confirmation.

Alternatives in the same family

  • I-PAN: Pannelli LED professionali UGR<19
  • CIELO Low UGR RD3013: Downlight LED da incasso UGR<19 · Lumileds 3030
  • WALL A/B Medium 15W×2: Applique Up&Down IP65 · DALI-2 · 30W
  • WALL A/B 1750: Applique lineare ultra-slim 1725 mm · 46W · CREE Premium

In short

ALTAVIA Pannel LED BK Lite is a defensible choice when indoor lighting requirements are stated, the calculation reproduces the real geometry and commissioning follows an agreed protocol. The full datasheet and quotation request are on the product page: https://lumeitalia.it/prodotti/altavia-pannel-bk-lite. The technical office is available for design requirement reviews at info@lumeitalia.it.

Domande frequenti

Which projects should consider ALTAVIA Pannel LED BK Lite?+

Indoor lighting projects covering offices, retail, schools, healthcare and commercial spaces. Suitability starts from scope classification and real geometry, not from datasheet comparison.

Which documents should be requested before specifying ALTAVIA Pannel LED BK Lite?+

Photometric files for the proposed luminaires, declaration of conformity, declared lifetime data per IES LM-80 with its conditions, maintenance schedule and warranty terms.

Is ALTAVIA Pannel LED BK Lite suitable for retrofitting an existing installation?+

It depends on the inherited geometry: existing spacings and heights must be checked with a dedicated calculation before confirming a one-for-one replacement. The technical office runs the check on request.

Why are photometric values not published?+

Because an out-of-context figure cannot be verified: the result depends on configuration, optic and installation geometry. Photometric files are available at info@lumeitalia.it.