The questions we receive about warehouse and logistics hub lighting
Short answers to the most frequent technical questions on warehouse and logistics hub lighting collected by the technical office.
Corsie di un magazzino con scaffalature alte e illuminazione LED. Immagine illustrativa generata con AI.
Overview
This note collects the technical questions most often received by Centro Studi Lumeitalia about warehouse and logistics hub lighting, with concise answers and references to the applicable standards. In logistics hubs lighting runs almost continuously and must follow narrow aisles, high racking and moving vehicles.
Applicable standards
The regulatory reference for warehouse and logistics hub lighting is not a single document but a coordinated set of standards covering performance, safety and environmental impact. In design practice the following documents drive the main choices.
EN 12464-1 — requirements for storage and picking areas.
Italian Legislative Decree 81/2008 — safety in materials handling.
EN 1838 — emergency lighting.
Which requirements apply?
The applicable references are those cited in this article; the choice of category or performance level depends on the intended use and must be justified in the design report. There is no absolute correct value: there is the right value for the case analysed, with its written justification.
How is the luminaire selected?
After defining requirements, not before. Selection is based on a photometric distribution suited to the geometry, compatibility with site environmental conditions, the planned control system and maintainability. The photometric file of the actually proposed luminaire is the document that makes the choice verifiable.
How long does a design review take?
Reviewing requirements and calculation assumptions on a documented project takes days, not weeks. Timescales stretch when the survey of the existing condition is missing or requirements were never declared: in that case the review becomes a redesign.
Who to contact
For reviewing requirements, specifications and verification protocols the Lumeitalia technical office is available. Technical requests can be addressed to the contacts published in the site contact section, stating the application field and available documentation.
Recurring critical points
The difficulties that most often emerge in warehouse and logistics hub lighting projects are not about product selection, but about defining requirements and verifying results.
Lighting the rack face, not only the aisle floor.
Avoiding glare for forklift operators.
Matching levels between automated and manned areas.
Design approach
An orderly method drastically reduces variations during works and disputes at commissioning. Three choices make the difference from the earliest stages.
Narrow-distribution optics aligned with the aisle axis.
Per-aisle control with dedicated sensors and standby levels.
Different requirements for picking, storage and loading docks.
Parameters to verify
Vertical illuminance — EN 12464-1 — label legibility on the rack face
Aisle uniformity — EN 12464-1 — continuity along the axis
UGR — EN 12464-1 — workstations and driving cabs
Emergency — EN 1838 — aisles and exits
Most frequent mistakes
Non-conformities found at commissioning almost always come from three causes: requirements not declared or declared without a reference standard, calculation run on idealised geometry, and an optimistic maintenance factor. All three can be avoided at zero cost during design.
Key takeaways
A warehouse and logistics hub lighting project holds up over time when requirements are declared, the calculation reproduces real conditions and on-site verification follows an agreed protocol. Component selection matters, but comes later: without measurable requirements even the best product delivers a result that cannot be demonstrated. Centro Studi Lumeitalia makes its technical office available to review requirements and design checks.
Methodological note: This content is written for technical information purposes by Centro Studi Lumeitalia and does not replace the lighting design or a full reading of the standards cited. Applicable performance values are those of the standards in force at design time.
Domande frequenti
Why does vertical illuminance matter in a warehouse?+
Because operators read codes and labels on the rack face, a vertical surface: an installation optimised only for the floor does not solve the visual task.
Are per-aisle sensors reliable with forklifts?+
Yes, if hold times and overlap zones are designed for vehicle speed, avoiding late switch-on.
Where should a warehouse and logistics hub lighting project start?+
From a written definition of performance requirements and verification conditions: this step drives every later choice and makes the result either disputable or defensible at commissioning.
Which documents should be requested from the supplier?+
Photometric files of the proposed luminaires, declaration of conformity, lifetime data declared per IES LM-80 with its conditions, the maintenance schedule and warranty terms.
Lumeitalia — Sistemi LED professionali
Lumeitalia è il brand di illuminazione LED professionale di Mya Tech S.r.l., azienda italiana fondata nel 2011 a Trezzano sul Naviglio (MI); il brand è attivo dal 2020.