How demand is changing in motorway and major-artery lighting
The requests most often arriving in motorway and major-artery lighting projects and what they say about the market.
Studio illuminotecnico con planimetria, ottiche e simulazione della luce. Immagine illustrativa generata con AI.
Overview
The requests reaching the technical office are a reliable indicator of how the market is changing. On motorways and main extra-urban roads, lighting is concentrated on interchanges, service areas and high-risk sections, where visual continuity is a safety requirement. This note summarises the trends observed in motorway and major-artery lighting projects, with no numerical projections or sector estimates.
Applicable standards
The regulatory reference for motorway and major-artery lighting is not a single document but a coordinated set of standards covering performance, safety and environmental impact. In design practice the following documents drive the main choices.
EN 13201-2 — M classes for fast motorised traffic.
CIE 140 — road lighting calculation methods.
UNI 11248 — class selection and adaptive downgrading.
What is requested most often
Three requests recur with growing frequency: complete documentation accompanying the supply, guaranteed spare-part availability over a multi-year horizon, and openness of control protocols. These shift attention from product to service and presuppose a long-term supply relationship.
What these requests indicate
They indicate that clients are internalising life-cycle cost in purchasing decisions. The practical consequence is that bid comparison shifts onto documentary and contractual elements, and that specifications must be more precise about what is required and how it will be verified.
In the specific field of motorway and major-artery lighting, the greatest sensitivity concerns avoiding abrupt transition zones between lit and unlit sections: it is the point where clarification requests concentrate during tenders.
Implications for designers and suppliers
For designers it means devoting more space to verification criteria and required documentation; for suppliers it means organising their documentation as part of the product rather than a later formality. Centro Studi Lumeitalia makes its technical office available to review tender documents.
Recurring critical points
The difficulties that most often emerge in motorway and major-artery lighting projects are not about product selection, but about defining requirements and verifying results.
Avoiding abrupt transition zones between lit and unlit sections.
Keeping maintenance feasible with minimal lane closures.
Withstanding vibration, de-icing salt and wind loads on high masts.
Design approach
An orderly method drastically reduces variations during works and disputes at commissioning. Three choices make the difference from the earliest stages.
Transition zones designed with a controlled luminance gradient.
Luminaires with fast access to the gear tray and replaceable components.
Remote management for diagnostics and fewer field interventions.
Parameters to verify
M class — EN 13201-2 — assigned by design speed and complexity
Surround ratio SR — EN 13201-2 — lighting of the lateral strips
Maintainability — specification — access without removing the optic
Mechanical resistance — EN 60598 — vibration and pole loads
Most frequent mistakes
Non-conformities found at commissioning almost always come from three causes: requirements not declared or declared without a reference standard, calculation run on idealised geometry, and an optimistic maintenance factor. All three can be avoided at zero cost during design.
Key takeaways
A motorway and major-artery lighting project holds up over time when requirements are declared, the calculation reproduces real conditions and on-site verification follows an agreed protocol. Component selection matters, but comes later: without measurable requirements even the best product delivers a result that cannot be demonstrated. Centro Studi Lumeitalia makes its technical office available to review requirements and design checks.
Methodological note: This content is written for technical information purposes by Centro Studi Lumeitalia and does not replace the lighting design or a full reading of the standards cited. Applicable performance values are those of the standards in force at design time.
Domande frequenti
Why are motorways not lit end to end?+
Because continuous lighting is not always the most effective safety measure: standards and design practice concentrate it on interchanges, conflict areas, tunnels and sections with documented accident rates.
How is the transition between lit and dark sections handled?+
With a transition zone of decreasing luminance, allowing the driver's visual adaptation and avoiding the black-hole effect.
Where should a motorway and major-artery lighting project start?+
From a written definition of performance requirements and verification conditions: this step drives every later choice and makes the result either disputable or defensible at commissioning.
Which documents should be requested from the supplier?+
Photometric files of the proposed luminaires, declaration of conformity, lifetime data declared per IES LM-80 with its conditions, the maintenance schedule and warranty terms.
Lumeitalia — Sistemi LED professionali
Lumeitalia è il brand di illuminazione LED professionale di Mya Tech S.r.l., azienda italiana fondata nel 2011 a Trezzano sul Naviglio (MI); il brand è attivo dal 2020.