KIT RETROFIT RT: technical selection and application guide
What KIT RETROFIT RT is, which retrofit and refurbishment projects it fits, which regulatory requirements to verify and how to specify it.
Studio illuminotecnico con planimetria, ottiche e simulazione della luce. Immagine illustrativa generata con AI.
Overview
KIT RETROFIT RT — Soluzione rettangolare per riqualificazione. Kit retrofit rettangolare per lanterne con apertura rettangolare. Adatto a vecchi impianti. This Centro Studi briefing does not replace the product page: it frames the luminaire within the design process, from requirement definition to on-site verification.
Where it is used
KIT RETROFIT RT belongs to the retrofit and refurbishment scope and is used in existing installations upgraded while keeping poles, brackets and wiring. Three items always come first: classification of the scope under the applicable standard, the real installation geometry (spacings, heights, brackets or pitches) and the maintenance conditions planned over the installation life cycle.
Build characteristics
Photometric data: Specific photometric values (flux, efficacy, expected illuminance) are not published in generic form because they depend on configuration and installation geometry. Photometric files for calculation are available from the technical office at info@lumeitalia.it.
Forma rettangolare
Retrofit versatile
Forma — Rettangolare
Protezione — IP67
CCT — 2200-5700K
CRI — 70/80/90
Controllo — On/Off
Regulatory requirements to verify
The requirement must be stated before product selection and repeated at commissioning with the same measurement method. A requirement written without a reference standard and without verification conditions is the most frequent cause of dispute at acceptance.
UNI 11248 / EN 13201 — performance verification after the works
IEC 60364 — electrical safety of the refurbished installation
GPP criteria — requirements for public refurbishment contracts
Scope classified under the applicable standard, with the risk analysis attached
Performance requirements stated with standard, measurement point and conditions
Maintenance factor justified and consistent with the cleaning plan
Photometric files requested from the supplier for the design calculation
Ingress protection, impact resistance and electrical class matched to the site
Dimming system and control protocol defined in the specification
Warranty terms, spare parts and maintenance accessibility
Installation, operation and maintenance
During installation the main variables are aiming, tightening of the fixings and correct execution of the electrical terminations. In operation, the maintenance plan must state the cleaning frequency of the optical surfaces, periodic gasket checks and how electronic components are replaced.
Declared marks and ratings for the range: ENEC, CE, IP67. The related documents are supplied with the order confirmation.
Alternatives in the same family
KIT RETROFIT RD: Soluzione rotonda per riqualificazione
KIT RETROFIT SQ: Soluzione quadrata per riqualificazione
KIT RETROFIT RT is a defensible choice when retrofit and refurbishment requirements are stated, the calculation reproduces the real geometry and commissioning follows an agreed protocol. The full datasheet and quotation request are on the product page: https://lumeitalia.it/prodotti/kit-retrofit-rt. The technical office is available for design requirement reviews at info@lumeitalia.it.
Domande frequenti
Which projects should consider KIT RETROFIT RT?+
Retrofit and refurbishment projects covering existing installations upgraded while keeping poles, brackets and wiring. Suitability starts from scope classification and real geometry, not from datasheet comparison.
Which documents should be requested before specifying KIT RETROFIT RT?+
Photometric files for the proposed luminaires, declaration of conformity, declared lifetime data per IES LM-80 with its conditions, maintenance schedule and warranty terms.
Is KIT RETROFIT RT suitable for retrofitting an existing installation?+
It depends on the inherited geometry: existing spacings and heights must be checked with a dedicated calculation before confirming a one-for-one replacement. The technical office runs the check on request.
Why are photometric values not published?+
Because an out-of-context figure cannot be verified: the result depends on configuration, optic and installation geometry. Photometric files are available at info@lumeitalia.it.