Overview
Savings claimed at bid stage and savings proven in operation coincide only when a properly built baseline exists. In logistics hubs lighting runs almost continuously and must follow narrow aisles, high racking and moving vehicles. This Centro Studi Lumeitalia piece describes how to set up measurement and verification in a warehouse and logistics hub lighting intervention.
Applicable standards
The regulatory reference for warehouse and logistics hub lighting is not a single document but a coordinated set of standards covering performance, safety and environmental impact. In design practice the following documents drive the main choices.
EN 12464-1 — requirements for storage and picking areas.
Italian Legislative Decree 81/2008 — safety in materials handling.
EN 1838 — emergency lighting.
Building the baseline
The baseline is not installed power: it is actual consumption over the reference period, reconstructed from meter readings or bills, tied to real operating hours and the period's operating conditions. Any switched-off or failed luminaires must be documented, because including non-working units inflates the savings artificially.
In warehouse and logistics hub lighting contexts it is also worth noting planned changes in use after the intervention: a change in schedule or intended use alters consumption regardless of the installed technology.
Independent variables and adjustments
The before/after comparison requires declaring which variables may change and how data is corrected: operating hours, served area or length, dimming profile, any extensions. Without written adjustment rules, every deviation becomes a negotiation at the first unusual energy bill.
Measurement instruments and observation period
Measurement can be spot-based (campaigns on representative circuits) or continuous (dedicated meters, data from the remote management system). Continuous measurement is preferable when a guaranteed-performance contract is in place. In any case the post-intervention observation period must cover operating conditions comparable with the baseline.
The result must be reported in a document stating method, raw data, applied adjustments and net savings. It is the document that turns savings into data rather than a marketing claim.
Recurring critical points
The difficulties that most often emerge in warehouse and logistics hub lighting projects are not about product selection, but about defining requirements and verifying results.
Lighting the rack face, not only the aisle floor.
Avoiding glare for forklift operators.
Matching levels between automated and manned areas.
Design approach
An orderly method drastically reduces variations during works and disputes at commissioning. Three choices make the difference from the earliest stages.
Narrow-distribution optics aligned with the aisle axis.
Per-aisle control with dedicated sensors and standby levels.
Different requirements for picking, storage and loading docks.
Parameters to verify
Vertical illuminance — EN 12464-1 — label legibility on the rack face
Aisle uniformity — EN 12464-1 — continuity along the axis
UGR — EN 12464-1 — workstations and driving cabs
Emergency — EN 1838 — aisles and exits
Most frequent mistakes
Non-conformities found at commissioning almost always come from three causes: requirements not declared or declared without a reference standard, calculation run on idealised geometry, and an optimistic maintenance factor. All three can be avoided at zero cost during design.
Baseline rebuilt from actual consumption, not installed power
Switched-off or failed luminaires documented in the baseline
Independent variables and adjustment rules written down
Chosen measurement method (spot or continuous) justified
Comparable post-intervention observation period
Final report with raw data, adjustments and net savings
Key takeaways
A warehouse and logistics hub lighting project holds up over time when requirements are declared, the calculation reproduces real conditions and on-site verification follows an agreed protocol. Component selection matters, but comes later: without measurable requirements even the best product delivers a result that cannot be demonstrated. Centro Studi Lumeitalia makes its technical office available to review requirements and design checks.
Methodological note: This content is written for technical information purposes by Centro Studi Lumeitalia and does not replace the lighting design or a full reading of the standards cited. Applicable performance values are those of the standards in force at design time.
Domande frequenti
Why does vertical illuminance matter in a warehouse?+
Because operators read codes and labels on the rack face, a vertical surface: an installation optimised only for the floor does not solve the visual task.
Are per-aisle sensors reliable with forklifts?+
Yes, if hold times and overlap zones are designed for vehicle speed, avoiding late switch-on.
Where should a warehouse and logistics hub lighting project start?+
From a written definition of performance requirements and verification conditions: this step drives every later choice and makes the result either disputable or defensible at commissioning.
Which documents should be requested from the supplier?+
Photometric files of the proposed luminaires, declaration of conformity, lifetime data declared per IES LM-80 with its conditions, the maintenance schedule and warranty terms.
Lumeitalia — Sistemi LED professionali
Lumeitalia è il brand di illuminazione LED professionale di Mya Tech S.r.l., azienda italiana fondata nel 2011 a Trezzano sul Naviglio (MI); il brand è attivo dal 2020.