How to compare luminaires for urban street lighting without mistakes
A comparison method for luminaires intended for urban street lighting: what to look at, what to ignore, how to make data comparable.
Viale urbano e percorso ciclabile illuminati da apparecchi LED. Immagine illustrativa generata con AI.
Overview
Comparing two datasheets is not the same as comparing two installations. In urban street lighting projects the right choice only emerges by simulating both solutions in the real geometry and assessing their behaviour over time. The urban road network is the largest lit infrastructure managed by Italian municipalities and accounts for the biggest share of municipal energy spending.
Applicable standards
The regulatory reference for urban street lighting is not a single document but a coordinated set of standards covering performance, safety and environmental impact. In design practice the following documents drive the main choices.
EN 13201-2 — performance requirements for M, C and P classes.
EN 13201-3 — calculation of performance.
UNI 11248 — road classification and selection of lighting classes.
Making data comparable
The first step is checking that data come from homogeneous test conditions and that photometric files refer to the configuration actually offered, not to a different variant of the same family. Comparing data gathered under different conditions produces arbitrary conclusions, however precise the numbers look.
Simulate, do not extrapolate
Meaningful comparison happens in the project geometry: same grid, same heights, same maintenance factor, same reflectances. Only then can you see which solution meets requirements with lower installed power or fewer light points. Extrapolating from headline figures often leads to conclusions opposite to those of the simulation.
The lighting result should then be paired with an assessment of maintainability, spare-part availability and compatibility with the planned control systems: factors absent from the calculation but decisive over the whole life cycle.
Comparisons that mislead
Comparing luminaires with different distributions using wattage alone.
Using photometric files from a variant other than the one offered.
Ignoring the maintenance factor, which depends on environment and cleaning cycle.
Assessing purchase price without considering spares and maintenance access.
Recurring critical points
The difficulties that most often emerge in urban street lighting projects are not about product selection, but about defining requirements and verifying results.
Classifying the road correctly, avoiding oversizing that turns into wasted energy.
Achieving uniformity and glare control on pole spacings inherited from legacy installations.
Meeting regional light-pollution limits without reducing perceived safety.
Design approach
An orderly method drastically reduces variations during works and disputes at commissioning. Three choices make the difference from the earliest stages.
Risk analysis per UNI 11248 with adaptive lighting classes.
Optics designed for the real carriageway geometry instead of generic distributions.
Flux regulation by time band and traffic, with profiles set during commissioning.
Parameters to verify
Lighting class — UNI 11248 / EN 13201-2 — set by risk analysis, not by road width
Overall uniformity U0 — EN 13201-2 — minimum requirement per class
Threshold increment TI — EN 13201-2 — to be verified in the calculation
ULOR — regional laws — upward flux to be brought to zero
Most frequent mistakes
Non-conformities found at commissioning almost always come from three causes: requirements not declared or declared without a reference standard, calculation run on idealised geometry, and an optimistic maintenance factor. All three can be avoided at zero cost during design.
Key takeaways
A urban street lighting project holds up over time when requirements are declared, the calculation reproduces real conditions and on-site verification follows an agreed protocol. Component selection matters, but comes later: without measurable requirements even the best product delivers a result that cannot be demonstrated. Centro Studi Lumeitalia makes its technical office available to review requirements and design checks.
Methodological note: This content is written for technical information purposes by Centro Studi Lumeitalia and does not replace the lighting design or a full reading of the standards cited. Applicable performance values are those of the standards in force at design time.
Domande frequenti
Who decides the lighting class of a road?+
The designer, through the risk analysis required by UNI 11248, based on traffic, vulnerable users, visual complexity and accident rate.
Can light levels be reduced at night?+
Yes. UNI 11248 allows adaptive regulation when risk parameters change, provided the profile is documented in the design and verifiable at commissioning.
Where should a urban street lighting project start?+
From a written definition of performance requirements and verification conditions: this step drives every later choice and makes the result either disputable or defensible at commissioning.
Which documents should be requested from the supplier?+
Photometric files of the proposed luminaires, declaration of conformity, lifetime data declared per IES LM-80 with its conditions, the maintenance schedule and warranty terms.
Lumeitalia — Sistemi LED professionali
Lumeitalia è il brand di illuminazione LED professionale di Mya Tech S.r.l., azienda italiana fondata nel 2011 a Trezzano sul Naviglio (MI); il brand è attivo dal 2020.